Re: PA-2T3 in Flexwan on 6509?

From: Jared Mauch (jared@puck.nether.net)
Date: Sun Jan 27 2002 - 12:00:44 EST


        w/ sup1-mfsc2 and native i *HIGHLY* recommend running
12.1(8b)E8 which was recently released.

        This has a number of very important fixes that can cause the
router to crash that were fixed in E6,E7 and E8

        - Jared

On Sat, Jan 26, 2002 at 03:26:30PM -0500, Alex Rubenstein wrote:
>
> I've got one here.
>
> And, yes, I've searched cco, and yes, I've opened a ticket with the TAC;
> both to no avail.
>
> I've a Sup-1, MSFC2 6509 with two flexwan cards in it. One flexwan has two
> pa-a3-oc3mm's, and the other has one PA-2T3 and one PA-2T3+.
>
> We can't get the PA-2T3's to work; we're sure it's not the cards (we
> tested them elsewhere), and we're sure it's not the flexwan (we swapped
> with the one with the Pa-A3's, and it worked).
>
> The interfaces are there, but no packets ever come 'in'. Even now, we have
> a coax-hard-loop towards the card.
>
> 0 packets input, 0 bytes, 0 no buffer
> 45 packets output, 590 bytes, 0 underruns
>
> We've tried PPP, HDLC, and Frame-relay.
>
> 12.1(8a)E5 running in native.
>
> any tips, tricks, pointers? Anyone else seen this?
>
>
>
> -- Alex Rubenstein, AR97, K2AHR, alex@nac.net, latency, Al Reuben --
> -- Net Access Corporation, 800-NET-ME-36, http://www.nac.net --
>

-- 
Jared Mauch  | pgp key available via finger from jared@puck.nether.net
clue++;      | http://puck.nether.net/~jared/  My statements are only mine.



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:01 EDT