RE: [nsp] Environmental Monitor initiated shutdown on UBR7246VXR

From: KF (kf@reign.sk)
Date: Thu Jan 31 2002 - 10:19:38 EST


hmmm can you post how sh environment table looks like?

alex

> -----Original Message-----
> From: Tejal Shah [mailto:tejal.shah@surat.iqara.net]
> Sent: Thursday, January 31, 2002 1:52 PM
> To: cisco-nsp@puck.nether.net
> Subject: [nsp] Environmental Monitor initiated shutdown on UBR7246VXR
>
>
> Hi all,
>
> I am getting following error when i reboot my ubr7246VXR
> CMTS with NPE-400.
>
> ========================================================
> 00:00:52: %SYS-3-LOGGER_FLUSHING: System pausing to ensure
> console debugging output.
>
> 00:00:06: %UBR7200-3-CONFIG: Exceeds 600 bandwidth points
> for slots 0, 1, 3 & 5
> 00:00:09: %LINK-3-UPDOWN: Interface FastEthernet0/0,
> changed state to up
> 00:00:09: %LINK-3-UPDOWN: Interface GigabitEthernet1/0,
> changed state to up
> 00:00:09: %LINK-3-UPDOWN: Interface Cable3/0, changed state
> to up
> 00:00:09: %LINK-3-UPDOWN: Interface Cable4/0, changed state
> to up
> 00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> FastEthernet0/0, changed state to up
> 00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> GigabitEthernet1/0, changed state to down
> 00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> Cable3/0, changed state to up
> 00:00:10: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> Cable4/0, changed state to up
> 00:00:17: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> FastEthernet0/0, changed state to down
> 00:00:38: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> Cable3/0, changed state to down
> 00:00:38: %LINEPROTO-5-UPDOWN: Line protocol on Interface
> Cable4/0, changed state to down
> 00:00:52: %UBR7200-0-TEMPHIGH: measured at 21C/69F is too
> high: shutdown temperature 0C/32F
> 00:00:52: %ENVM-0-SHUT: Environmental Monitor initiated
> shutdown
> Buffered messages
> =========================================================
>
> Pl. help me out to resolve this problem.
>
> thanks in advance
> Tejal Shah
>
>
> Go To http://www.iqara.net
>
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:02 EDT