I've got a customer to which connects to us via a point-to-point T1. We 
configured the router (a 1720, ios 12.0(5)) on their side, and are using 
CBAC. They've not really had any complaints until now. There is one 
particular important website that they need access to. Getting to it is so 
slow as to be unusable. In troubleshooting, I've noticed that telnetting to 
the http port from inside their lan and doing a 'GET /' send back the page 
rather slowly, with lots of hesitation. If I then telnet to the http port 
from the router itself (bypassing the 'ip inspect' statement on the 
Ethernet port), it seems fine...nice and fast and no pauses. The timeout in 
the ip inspect http statement was 3600, but I changed it to 7200 to see 
what would happen. It's still the same. How can I figure out why this is 
happening? Does the router need more memory (or maybe replacing)?
Thanks!
Steve Pfister
srp336@getcoactive.com
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:04 EDT