Re: [nsp] unable to collect interface stats on 6905 MSFC2

From: Mike Axelrod (maxelrod@digisle.net)
Date: Fri Mar 01 2002 - 13:41:21 EST


I think you need to run CatOS 7.1 in order to get accurate counters for MLS
switched packets from MSFC.
Mike
----- Original Message -----
From: "matthew zeier" <mrz@intelenet.net>
To: <dtodd@partners.org>; <cisco-nsp@puck.nether.net>
Sent: Friday, March 01, 2002 10:03 AM
Subject: Re: [nsp] unable to collect interface stats on 6905 MSFC2

> >
> > -----BEGIN PGP SIGNED MESSAGE-----
> > Hash: SHA1
> >
> > Matt:
> >
> > What does the sh int vlan X show for stats? Is the counter here
> > increasing the same as the in/out octets?
>
> It increases at the same rate as IfOutOctets and IfInOctets however, the
> delta isn't great enough to match the 10.6Mbps I show on the switch port
or
> the customer's router port to me.
>
> - mz
>
> >
> > ==DMT>
> >
> > - ----SIGNATURE------
> > Douglas M. Todd, Jr.
> > CCNP
> > Network Engineering
> > Partners Health Care
> > Building 149
> > 149 13 Street
> > Charlestown, MA 02129-200
> > Tel: 617.726.1403
> > Email: dtodd@partners.org
> > - --------------------------------------------------------------------
> > PGP Finger Print: 9429 CAE3 B2D1 C2E1 DFBC E7A6 E90A 9BE5 C7B6 47BC
> > Key
> > available:http://keyserver.pgp.com:80/pks/lookup?op=get&exact=off&sear
> > ch=dtodd%40partners.org
> > Verisign S/N: 3ff65cdf58b9dceda004baeed49e16cf
> > https://digitalid.verisign.com/services/client/index.html
> >
> > >-----Original Message-----
> > >From: matthew zeier [mailto:mrz@intelenet.net]
> > >Sent: Friday, March 01, 2002 10:24 AM
> > >To: cisco-nsp@puck.nether.net
> > >Subject: [nsp] unable to collect interface stats on 6905 MSFC2
> > >
> > >
> > >
> > >I'm trying to run cricket against the Vlan interfaces on a
> > >6905 "router" and
> > >have noticed that IfOutOctets and IfInOctets barely
> > >incremenet, if at all.
> > >They do, however, if I query the switch but often customers are
> > >spread across several switches/switch ports and I wanted any easy
> > >way to grab inter-Vlan bandwidth.
> > >
> > >Running 12.1(8a)E2 and 6.3(3) .
> > >
> > >Any ideas?
> > >
> > >--
> > >matthew zeier - "In mathematics you don't understand things. You
> > >just get used to them." - Johann von Neumann
> >
> > -----BEGIN PGP SIGNATURE-----
> > Version: PGP 7.0
> >
> > iQA/AwUBPH++PggiZycqTvq3EQK6AQCePGNrJrmx8k0U/oE2IfuDGsvqT6AAoO0w
> > xoUdPUPt49GrDh3LhcvZZOMT
> > =5xYd
> > -----END PGP SIGNATURE-----
> >
> >
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:07 EDT