You need to define "wire speed" then. For example, the 3 port GE card
requires 3G (easy math) of switch fabric capacity to the backplane, but
there is only ~2.8G available. Therefore under 100% utilisation, this card
it is not "wire speed" - Cisco will tell you it's oversubscribed.
Matt.
-----Original Message-----
From: Greene, Patrick [mailto:pjgreene@infotechent.net]
Sent: 02 March 2002 02:07
To: Hank Nussbacher; cisco-nsp@puck.nether.net
Subject: RE: [nsp] GSR GigaE pps
You can expect full wire speed performance from all Gig ports on the GSR. I
have tested this personally.
Thanks,
Patrick
-----Original Message-----
From: Hank Nussbacher [mailto:hank@att.net.il]
Sent: Thu 2/28/2002 2:00 PM
To: cisco-nsp@puck.nether.net
Cc:
Subject: [nsp] GSR GigaE pps
I know that a GigaE interface on a 7500, even with a VIP4-80 will top out
at 200kpps. Has anyone done benchmarks on GSR GigaE interfaces? What is
the top value you have seen on the following cards:
Engine 1: 1-Port GE w/ ECC
Engine 2: 3-Port GE
Engine 4: 10-Port GE
Thanks,
Hank
------------------------------------------------------------------------------
Live Life in Broadband
www.telewest.co.uk
The information transmitted is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material.
Statements and opinions expressed in this e-mail may not represent those of the company. Any review, retransmission, dissemination or other use of, or taking of any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this in error, please contact the sender immediately and delete the material from any computer.
==============================================================================
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:07 EDT