Re: [nsp] HSSI to G703 converter

From: Gert Doering (gert@greenie.muc.de)
Date: Fri Apr 12 2002 - 13:17:44 EDT


Hi,

On Fri, Apr 12, 2002 at 10:38:20AM -0600, Jeronimo Diez de Sollano Velazco Aceves wrote:
> Does anyone to recommend any HSSI to G703 interface converter for an E3 ???

We use the ADC Kentrox DataSmart iDSU. It can do E3 and T3, and "just
works".

Due to better monitoring capabilities, we prefer PA-E3/PA-T3's to HSSI,
though. If only cisco would finally deliver a NM-E3/T3 for the 36xx...

gert

-- 
USENET is *not* the non-clickable part of WWW!
                                                           //www.muc.de/~gert/
Gert Doering - Munich, Germany                             gert@greenie.muc.de
fax: +49-89-35655025                        gert.doering@physik.tu-muenchen.de



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:11 EDT