when you do a 'sh int s2/5', are you seeing any interface resets?
At 04:16 PM 12/12/97 -0500, you wrote:
>
>Seeing a lot of line protocol bounces on T1's in log files:
>
>For example:
>
>Dec 10 02:48:27 e1-1.baltimore.mae-east.clark.net 111498:
>%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial2/5, changed state
>to down
>Dec 10 02:48:27 e1-1.baltimore.mae-east.clark.net 111499:
>%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial2/5, changed state
>to up
>
>
>
>
>Bounces up and down in < 1 second - logs only show it for one end of the
>T1 not the other.
>
>Not sure if this is real, false positives, etc..
>
>Anyone seen this before?
>
> Stb
>
>
>
>
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
* Luke Parrish * Email lparrish@iamerica.net *
* LDS-iAmerica, ISP * Email luke@ciscokid.iamerica.net *
* Network Engineer * Phone 1-800-789-6062 x3010 *
* AS 4958 * http://cust.iamerica.net/lparrish *
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
* I love the Internet, and you should too. *
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:14 EDT