Well,
Looks like your Ethernet underflow(ed) - obviously. Meaning that the
interface driver didn't pull bits out of queue fast enough - normally a
microcode issue. You need a sho ver and a sho mic and a sh diag.
At 07:20 PM 1/16/98 +0800, you wrote:
>Folks
>
>Does anyone know what the following error messages that appear from
>our cisco routers mean ?
>
>This is a spurious message that seems to have transitioned our
>serial connection.
>
>
>Jan 12 08:06:13 net-gw 175: %LANCE-3-UNDERFLO: Unit 0, underflow error
>Jan 13 19:12:49 net-gw 178: %LANCE-3-UNDERFLO: Unit 0, underflow error
>Jan 14 07:37:08 net-gw 180: %LINK-3-UPDOWN: Interface Serial0, changed state
>to down
>Jan 14 07:37:12 net-gw 181: %LINK-3-UPDOWN: Interface Serial0, changed state
>to up
>
>Appreciate any advise you may have.
>
>Best Regards
>
>-rc
>
>