PXF External memory exception

From: Brian Wallingford (brian@meganet.net)
Date: Thu Oct 18 2001 - 13:42:27 EDT


Hello,

Upon enabling PXF on 2 border routers, I received the identical error on
each. The only info I can find on Cisco's site is the suggestion to
reload. Upon reload, the same errors occur. Logging during boot:

Oct 17 21:09:18: %PXF-2-EXCEPTION: PXF exception on unit tmc.
Oct 17 21:09:21: %PXF-2-RESTARTED: PXF tmc restarted.
Oct 17 21:09:21: %PXF-2-EXCEPTION: PXF exception on unit tmc.
Oct 17 21:09:24: %PXF-2-RESTARTED: PXF tmc restarted.
Oct 17 21:09:24: %PXF-2-EXCEPTION: PXF exception on unit tmc.
Oct 17 21:09:27: %PXF-2-RESTARTED: PXF tmc restarted.
Oct 17 21:09:27: %PXF-2-EXCEPTION: PXF exception on unit tmc.
Oct 17 21:09:30: %PXF-2-RESTARTED: PXF tmc restarted.
Oct 17 21:09:30: %PXF-2-EXCEPTION: PXF exception on unit tmc.
Oct 17 21:09:30: %PXF-2-DISABLED: PXF tmc disabled (too many restarts).

and

border1.bos.ma#sh pxf cra
PXF tmc:
MAC XID: 00000004 IHB status: 0xB7FFB003
External memory exception on column 2 (0x00000010)

Running 12.2(4)T on a 7206vxr w/NSE-1 (haven't found any bug reports or
caveats for this rev).

Any ideas, or suggestions for a rev which supports PXF well?

tia,
brian