Hi,
The range for DLCI's for use with CCC is 512 through 1022. You may use
a different DLCI value at either side of the connection as long as that
range is observed. DLCI values below 512 are reserved for standard
frame-relay encaps and this encapsulation type may be assigned to any of
our Sonet interfaces.
Hope this helps.
Bob O'Hara
Systems Engineer
Juniper Networks
Northeast Sales Region
.........................................
. email: <mailto:rohara@juniper.net> rohara@juniper.net .
. cell: 603.498.8119 .
. home office: 603.382.3894 .
.........................................
-----Original Message-----
From: caspar_weru [mailto:caspar_weru@hotmail.com]
Sent: Friday, August 24, 2001 12:18 AM
To: juniper-nsp@puck.nether.net
Subject: [j-nsp] FR DLCI over MPLS using CCC
Hi,
I want to carry FR over MPLS using CCC.
Do I need to maintain the same DLCI for both point A and B or I can use
different range of DLCI for point A and B.
Thx for u'r help.
This archive was generated by hypermail 2b29 : Mon Aug 05 2002 - 10:42:36 EDT