('binary' encoding is not supported, stored as-is)
Hi Steve,
Thanks for your help.
Actually, the command is
set system port type vt100 --> for console session
or
set system aux type vt100 --> for aux session
cause
set cli terminal vt100 just only for a session.
regards
jakasemboeng
> -----Original Message-----
> From: Stephen Gill [mailto:gillsr@yahoo.com]
> Sent: Thursday, August 30, 2001 9:50 PM
> To: 'jakasemboeng'; 'Aviva Garrett'
> Cc: 'Juniper-Nsp'
> Subject: RE: Monitoring Real time traffic in Junos 4.4
>
>
> This is probably because you have not set your terminal type. The monitor
> interface traffic command still works as expected.
>
> Try this:
> set cli terminal vt100
> monitor interface traffic
>
> Cheers,
> -- steve
>
> -----Original Message-----
> From: jakasemboeng [mailto:jakasemboeng@ekilat.com]
> Sent: Thursday, August 30, 2001 3:50 AM
> To: Aviva Garrett
> Cc: Juniper-Nsp
> Subject: Monitoring Real time traffic in Junos 4.4
>
>
>
> Hi all,
>
> I need your help asap.
>
> In Junos 4.3, if I want to monitor real-time, I just type "monitor
> interface {interface|traffic}"
>
> But in Junos 4.4, I could't do the same thing to monitor
> real-time traffic.
> When I issued the command "monitor interface traffic" and I got error
> message "error opening terminal: unknown"
>
> juniper@M10> monitor interface traffic
> Error opening terminal: unknown.
>
>
> Have you any idea for monitoring real-time traffic in Junos 4.4 ?
>
> Please, let me know....
> Thanks for your attention
>
>
> thanks
> jakasemboeng
>
>
> _________________________________________________________
> Do You Yahoo!?
> Get your free @yahoo.com address at http://mail.yahoo.com
>