Hi,
The default maximum setting for sampling is 1000pps per
active switch fabric. On the M160, because it has four switch
fabs, the default is 4000pps. As Steve has noted in his earlier
email, you can configure the router to provide more than 1000pps
under the [edit forwarding-options] heirarchy, use the
'set sampling max-packets-per-second x', where x is the max number
of packets per second you define. Juniper's recommended guideline
to customers is to stick with the default of 1000pps/switch fabric.
This has been tested and is certified.
Also, while using the run-rate is useful in some circumstances,
if you are truly trying to capture a representative sample
of the flows that are running through the box, then a run-rate
greater than '1' will skew your results.
Thanks,
Bob O'Hara
Systems Engineer
Juniper Networks
Northeast Sales Region
.........................................
. email: rohara@juniper.net .
.........................................
-----Original Message-----
From: Stephen Gill [mailto:gillsr@yahoo.com]
Sent: Wednesday, November 07, 2001 4:39 PM
To: 'Przemyslaw Karwasiecki'; juniper-nsp@puck.nether.net
Subject: RE: [j-nsp] cflowd sampling
Unfortunately you are limited by a 100-Mbps bus b/n the RE and PFE
(fxp1). For this reason, the number of packets that you can sample is
limited, thus the need for telling the router what you really want to
classify as interesting. You can be as granular as you would like when
doing so, such as by sampling syn/fin packets, etc... Keep in mind that
there is a built in rate-limiting mechanism of 7000pps no matter how
much you may try to sample.
It will be difficult to measure a full flow (including ack packets) if
you cannot sample ALL traffic. As long as you stay within the built in
limitations of pps you can sample based on filters.
According to the docs on the 'run-length' flag: "Set the number of
samples following the initial trigger event, thus allowing you to sample
adjacent packets to those already being sampled." IE. A run-length of
0 will not sample any other packets in addition to the first one - this
is the behavior you have noticed.
You may also wish to visit the juniper-nsp archives for previous posts
on netflow here: http://puck.nether.net/lists/juniper-nsp/
Juniper has posted a relevant Whitepaper on accounting that you may find
useful here: http://www.juniper.net/techcenter/techpapers/200010.pdf
Cheers,
-- steve
> -----Original Message-----
> From: Przemyslaw Karwasiecki [mailto:karwas@ifxcorp.com]
> Sent: Wednesday, November 07, 2001 10:46 AM
> To: juniper-nsp@puck.nether.net
> Subject: [j-nsp] cflowd sampling
>
> All,
>
> I am looking for some more detail descriptions how traffic sampling
> really work.
>
> I have just setup cflowd with 'rate 100' 'and run-length 1',
> and the results given by cfdnexthops are far different from
> what I would expect. Specifically traffic reported by this utility
> is approximately 2% of traffic which is actually send over each
> of the next hops.
> Because of rate ratio and run-length, I would expect to see 1%
> of traffic to be reported.
>
> Also, cflowd is actually meant to work on flow data, and I don't
> understand how you can identify full flows, from SYN/ACK to FIN
> just by looking at every 100ths packet. Or I am missing something.
>
> Any help, pointers, suggestions, explanations will be greatly
appreciated.
>
> TIA,
>
> Przemek