[j-nsp] AW: [j-nsp] AW: [j-nsp] Hot-plugable power-supplies in a M20 ?

From: Strahler, Carsten (Carsten.Strahler@lambdanet.net)
Date: Thu Dec 13 2001 - 11:37:22 EST


Hi,

both power supplies are up and running. Is there a configuration statement
in JUNOS to activate the redundancy ?

Carsten

> -----Ursprungliche Nachricht-----
> Von: Markolf Gudjons [mailto:eedmgu@eed.ericsson.se]
> Gesendet: Donnerstag, 13. Dezember 2001 16:55
> An: Strahler, Carsten
> Cc: Juniper-Nsp (E-Mail)
> Betreff: Re: [j-nsp] AW: [j-nsp] Hot-plugable power-supplies
> in a M20 ?
>
>
> Carsten,
>
> On Thu, 13 Dec 2001, Strahler, Carsten wrote:
>
> > sorry for my imprecise reading of the manual. But it *reboots* after
> > turning on the replaced PSU. We tested this on two M20s.
> I just went over and flicked the switch on one of ours. It
> doesn't reboot.
>
> So something must be wrong with your box. Check if both power supplies
> come online and there are no alarms present.
>
> - Markolf
>