Re: [j-nsp] Default-address-selection & T3 interfaces

From: Jeff Bartig (jeffb@doit.wisc.edu)
Date: Wed Feb 20 2002 - 16:46:16 EST


Neil,

When you did the ping that had the high packet loss, the ICMP echo
packets were using a source address of your loopback interface.
What route is the distant router taking to get back to your loopback
interface? My guess is that it is not taking the T3 back to you.
It is probably taking some other congested path.

ssh over to 80.74.163.22 (use "ssh source 80.74.163.21 80.74.163.22"
if you are using a new enough version of Junos). Do a "show route"
or "traceroute" to the loopback address of the first router.

Jeff

On Wed, Feb 20, 2002 at 07:19:10PM -0000, Neil Stirling wrote:
> Hi all,
>
> Has anyone found problems using default-address-selection enabled, and
> passing traffic across an T3 interface ?
>
> These results show 'das' disabled, and then a rapid ping, 'das' enabled and
> then a rapid ping, and then with an added source-address of the local
> interface.
>
> It seems that a problem exists between the physical interface (T3) and the
> pfe.
>
>
> ---------------
>
> nortel@NEC-01N-B03-01.0> ping 80.74.163.22 rapid count 1000
> PING 80.74.163.22 (80.74.163.22): 56 data bytes
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!
> --- 80.74.163.22 ping statistics ---
> 1000 packets transmitted, 1000 packets received, 0% packet loss
> round-trip min/avg/max/stddev = 3.500/3.651/46.861/1.729 ms
>
> nortel@NEC-01N-B03-01.0> edit
> Entering configuration mode
>
> [edit]
> nortel@NEC-01N-B03-01.0# set system default-address-selection
>
> [edit]
> nortel@NEC-01N-B03-01.0# commit synchronize
> Results from re1:
> configuration check succeeds
>
> Results from re1:
> commit complete
>
> commit complete
>
> [edit]
> nortel@NEC-01N-B03-01.0# exit
> Exiting configuration mode
>
> nortel@NEC-01N-B03-01.0> ping 80.74.163.22 rapid count 1000
> PING 80.74.163.22 (80.74.163.22): 56 data bytes
> !.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!.!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!.!!!!!!!!!!.!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!..!!!!!!!!.!!!!!!!!!!!!!!!!!!!!.!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!
> --- 80.74.163.22 ping statistics ---
> 1000 packets transmitted, 989 packets received, 1% packet loss
> round-trip min/avg/max/stddev = 9.894/30.092/260.973/34.182 ms
>
> nortel@NEC-01N-B03-01.0> ping 80.74.163.22 rapid count 1000 source
> 80.74.163.21
> PING 80.74.163.22 (80.74.163.22): 56 data bytes
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
> !!!!!!!!!!!!
> --- 80.74.163.22 ping statistics ---
> 1000 packets transmitted, 1000 packets received, 0% packet loss
> round-trip min/avg/max/stddev = 3.505/3.689/27.878/1.441 ms
>
> ----------------------------
>
> Its a T3 on 0/1/0 running JUNOS 5.1R1.4.
> No alarms exist on the chassis and both vty to fpc0 and scb are fine (no
> errors).
>
> :<( any ideas are appreciated !
>
>
> Neil.
>

-- 
Jeff Bartig                  |  University of Wisconsin - Madison
1210 W Dayton, Rm B263       |  Division of Information Technology
Work Phone: (608) 262-8336   |  Network Engineering Technology
E-Mail: jeffb@doit.wisc.edu  | 



This archive was generated by hypermail 2b29 : Mon Aug 05 2002 - 10:42:39 EDT