Re: [nsp] 7204VXR not recognizing FE interfaces

From: Gert Doering (gert@greenie.muc.de)
Date: Tue Dec 11 2001 - 14:47:36 EST


Hi,

On Tue, Dec 11, 2001 at 10:59:29AM -0600, Marius Strom wrote:
> Dealing with a brand-new out of the box 7204VXR with a c7200I/O-2FE/E
> board. The bootstrap recognizes the FE ports (12.1.8a-kboot), but
> putting a "normal" IOS image (tried with c7200-12.1-12-is56i-mz.bin) does
> not see the interfaces, and proceeds to give errors about environment
> monitoring (voltage levels, etc.). `show diag` gives a message about
> unknown Port Adapter type 533 in slot0, which is in fact the slot with
> the c7200I/O-2FE/E.

I didn't try 12.1(x) on a 2FE/E board yet. We use 12.0(x)S images, and
they properly recognize this board, and are much nicer overall anyway.

> Glancing back at various Cisco Press books point me nowhere, nor does
> google. Any ideas? If more info is needed, feel free to flame me and
> ask for more info and I'll provide what I can.

www.cisco.com should tell you something if you search for
"C7200-I/O-2FE/E minimum release" or so. Most likely it needs 12.1(x)T,
12.2(x) or 12.0(x)S.

gert

-- 
USENET is *not* the non-clickable part of WWW!
                                                           //www.muc.de/~gert/
Gert Doering - Munich, Germany                             gert@greenie.muc.de
fax: +49-89-35655025                        gert.doering@physik.tu-muenchen.de



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:57 EDT