On Tue, May 21, 2002 at 02:02:36PM -0400, Thomas Kernen wrote:
>
> We had this happen with a PA-A3-OC3MM today in a 7206VXR/400/2FE, the card
> is not recognized in the slot 2 but works fine in slot 6 (same PCI bus). We
> reinserted the card multiple times and still came up with the error. Defect
> slot?
Probably. Do you have another (known-good) card you could try in both
slots 6 and 2 to double-check?
eric
>
> May 21 13:24:59.244 UTC: %OIR-6-INSCARD: Card inserted in slot 2, interfaces
> administratively shut down
> May 21 13:25:00.244 UTC: %C7200-4-PCIVALID: PCI activation failed, bay 2,
> 0x11113104
> May 21 13:25:00.916 UTC: %PA-2-UNDEFPABRIDGE: Unsupported Port Adaptor
> Bridge 0xFFFFFFFF in bay 2
> May 21 13:25:00.916 UTC: %PA-3-DEACTIVATED: port adapter in bay [2] powered
> off.
> May 21 13:25:00.916 UTC: %PA-2-PABRIDGE: Failed to config bridge for PA 2
>
> Slot 2:
> Fast-ethernet port adapter, 1 port
> Port adapter is disabled deactivated
> Port adapter insertion time unknown
> EEPROM contents at hardware discovery:
> Hardware revision 0.0 Board revision UNKNOWN
> Serial number 0 Part number 00-0000-00
> Test history 0x0 RMA number 00-00-00
> EEPROM format version 0
> EEPROM contents (hex):
> 0x20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
> 0x30: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
>
> Thomas
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:11:57 EDT