Re: [nsp] unsupported PA in VXR

From: Thomas Kernen (tkernen@deckpoint.ch)
Date: Tue May 21 2002 - 15:55:41 EDT


> On Tue, May 21, 2002 at 02:02:36PM -0400, Thomas Kernen wrote:
> >
> > We had this happen with a PA-A3-OC3MM today in a 7206VXR/400/2FE, the
card
> > is not recognized in the slot 2 but works fine in slot 6 (same PCI bus).
We
> > reinserted the card multiple times and still came up with the error.
Defect
> > slot?
>
> Probably. Do you have another (known-good) card you could try in both
> slots 6 and 2 to double-check?
>

I'll try it next time around I have a spare/working PA to test in that
chassis.

Thomas

>
>
> >
> > May 21 13:24:59.244 UTC: %OIR-6-INSCARD: Card inserted in slot 2,
interfaces
> > administratively shut down
> > May 21 13:25:00.244 UTC: %C7200-4-PCIVALID: PCI activation failed, bay
2,
> > 0x11113104
> > May 21 13:25:00.916 UTC: %PA-2-UNDEFPABRIDGE: Unsupported Port Adaptor
> > Bridge 0xFFFFFFFF in bay 2
> > May 21 13:25:00.916 UTC: %PA-3-DEACTIVATED: port adapter in bay [2]
powered
> > off.
> > May 21 13:25:00.916 UTC: %PA-2-PABRIDGE: Failed to config bridge for PA
2
> >
> > Slot 2:
> > Fast-ethernet port adapter, 1 port
> > Port adapter is disabled deactivated
> > Port adapter insertion time unknown
> > EEPROM contents at hardware discovery:
> > Hardware revision 0.0 Board revision UNKNOWN
> > Serial number 0 Part number 00-0000-00
> > Test history 0x0 RMA number 00-00-00
> > EEPROM format version 0
> > EEPROM contents (hex):
> > 0x20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
> > 0x30: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
> >
> > Thomas