Use show diagbus, memory for FlexWAN is on a per PA basis.
bergen#sh diagbus
Slot 3: Logical_index 6
FlexWan controller
Board is analyzed ipc ready
HW rev 1.1, board revision A0
Serial Number: SAD041406ZK Part number: 73-3869-05
Slot database information:
Flags: 0x2004 Insertion time: unknown
Controller Memory Size:
56 MBytes CPU Memory
8 MBytes Packet Memory
64 MBytes Total on Board SDRAM
Memory Installed ********
IOS (tm) cwlc Software (cwpa-DW-M), Version 12.1(11b)EX, EARLY
DEPLOYMENT RELEASE SOFTWARE (fc1)
PA Bay 0 Information:
POS PA, 1 port, PA-POSSW-MM
EEPROM format version 1
HW rev 2.00, Board revision A0
Serial number: 21712915 Part number: 73-3192-02
Slot 3: Logical_index 7
FlexWan controller
Board is analyzed ipc ready
HW rev 1.1, board revision A0
Serial Number: SAD041406ZK Part number: 73-3869-05
Slot database information:
Flags: 0x2004 Insertion time: unknown
Controller Memory Size:
56 MBytes CPU Memory
8 MBytes Packet Memory
64 MBytes Total on Board SDRAM
Memory Installed ********
IOS (tm) cwlc Software (cwpa-DW-M), Version 12.1(11b)EX, EARLY
DEPLOYMENT RELEASE SOFTWARE (fc1)
PA Bay 1 Information:
2CT3+ single wide PA, 2 ports
EEPROM format version 1
HW rev 1.00, Board revision A0
Serial number: 21720787 Part number: 73-3388-03
At 10:22 AM 5/21/2002 -0500, Scott.Keoseyan@BroadWing.com wrote:
>Does anyone know the command to verify the size of the SODIMMs in a Cat6000
>flexwan module? I am having difficulty locating it on CCO.
>
>Scott
> +++The information transmitted is intended only for the person or entity to
>which it is addressed and may contain confidential and/or privileged
>material. Any review, retransmission, dissemination or other use of, or
>taking of any action in reliance upon, this information by persons or
>entities other than the intended recipient is prohibited. If you received
>this in error, please contact the sender and destroy any copies of this
>document.+++
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:44 EDT