On Wed, 22 Sep 1999 04:01:22 -0400
Steffen Baur <baur@noc.dfn.de> wrote:
> We experience RTTs around 1000ms to IP addresses on PA-A3
> subinterfaces, too. It can be fixed with a shutdown/ no shutdown of
> the subinterface. The high RTTs normally start after a crash of a VIP
> in another slot (which happens regularly recently :-( ).
>
I thought a shutdown / no shutdown on a subinterface took the entire
interface down?
Neil.
-- Neil J. McRae C O L T I N T E R N E T neil@COLT.NET
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:06 EDT