Re: [nsp] ICMP slowness on PA-A3 with lots of PVC's

From: Neil J. McRae (neil@COLT.NET)
Date: Wed Sep 22 1999 - 11:45:06 EDT


On Wed, 22 Sep 1999 04:01:22 -0400
 Steffen Baur <baur@noc.dfn.de> wrote:

> We experience RTTs around 1000ms to IP addresses on PA-A3
> subinterfaces, too. It can be fixed with a shutdown/ no shutdown of
> the subinterface. The high RTTs normally start after a crash of a VIP
> in another slot (which happens regularly recently :-( ).
>

I thought a shutdown / no shutdown on a subinterface took the entire
interface down?

Neil.

--
Neil J. McRae                             C O L T  I N T E R N E T
neil@COLT.NET