On Wed, Sep 22, 1999 at 04:45:06PM +0100, Neil J. McRae wrote:
> On Wed, 22 Sep 1999 04:01:22 -0400
> Steffen Baur <baur@noc.dfn.de> wrote:
>
> > We experience RTTs around 1000ms to IP addresses on PA-A3
> > subinterfaces, too. It can be fixed with a shutdown/ no shutdown of
> > the subinterface. The high RTTs normally start after a crash of a VIP
> > in another slot (which happens regularly recently :-( ).
> >
>
> I thought a shutdown / no shutdown on a subinterface took the entire
> interface down?
No, it doesn't.
/Jesper
-- Jesper Skriver (JS4261-RIPE), Network manager Tele Danmark DataNet, IP section (AS3292)One Unix to rule them all, One Resolver to find them, One IP to bring them all and in the zone to bind them.
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:06 EDT