I would format disk0:
then reload the images onto the flash card.
You should be ok then. I suspect there is no chkdsk disk0:
to fix bad FAT issues.
- Jared
On Mon, Dec 24, 2001 at 03:12:43PM +0300, Jen Linkova wrote:
> Hi All!
>
> I have some trouble with 7206VXR (sh ver is listed below)
> and PCMCIA Flash card (MEM-I/O-FLD48M)..
>
> CS7206-M9-2#dir disk0:
> Directory of disk0:/
>
> 1 -rw- 14127836 Aug 07 2001 07:44:32 c7200-js-mz.122-2.T1.bin
> 2 -rw- 5177344 Dec 18 2001 16:28:20 c7200-jk8s-mz.122-2.T1.bin
> 3 drw- 0 Dec 18 2001 16:51:56 testdir
>
> 47890432 bytes total (29163520 bytes free)
>
> Now I'm trying to delete c7200-jk8s-mz.122-2.T1.bin file.
>
> CS7206-M9-2#delete disk0:c7200-jk8s-mz.122-2.T1.bin
> Delete filename [c7200-jk8s-mz.122-2.T1.bin]?
> Delete disk0:c7200-jk8s-mz.122-2.T1.bin? [confirm]
> %Error deleting disk0:c7200-jk8s-mz.122-2.T1.bin (Failed Sector Read)
> CS7206-M9-2#
>
> But immediately after deleting:
> S7206-M9-2#dir disk0:
> Directory of disk0:/
>
> No files in directory
>
> 47890432 bytes total (0 bytes free)
> CS7206-M9-2#
>
> But:
> CS7206-M9-2#show file systems
> File Systems:
>
> Size(b) Free(b) Type Flags Prefixes
> * 47890432 29163520 disk rw disk0:
> .................
>
> and after 'sh file system' command:
>
> CS7206-M9-2#dir disk0:
> Directory of disk0:/
>
> 1 -rw- 14127836 Aug 07 2001 07:44:32 c7200-js-mz.122-2.T1.bin
> 2 -rw- 5177344 Dec 18 2001 16:28:20 c7200-jk8s-mz.122-2.T1.bin
> 3 drw- 0 Dec 18 2001 16:51:56 testdir
>
> 47890432 bytes total (29163520 bytes free)
>
> Has anyone seen this before, or perhaps even have a explanation
> for this behaviour?
> Is there a IOS bug or should I change PCMCIA card?
>
>
> -------- sh ver --------
> Cisco Internetwork Operating System Software
> IOS (tm) 7200 Software (C7200-JS-M), Version 12.2(2)T1, RELEASE SOFTWARE (fc2)
> TAC Support: http://www.cisco.com/tac
> Copyright (c) 1986-2001 by cisco Systems, Inc.
> Compiled Tue 17-Jul-01 17:21 by ccai
> Image text-base: 0x600089C0, data-base: 0x61818000
>
> ROM: System Bootstrap, Version 12.1(20000710:044039) [nlaw-121E_npeb 117], DEVELOPMENT SOFTWARE
> BOOTFLASH: 7200 Software (C7200-KBOOT-M), Version 12.1(8a)E, EARLY DEPLOYMENT RELEASE SOFTWARE (fc1)
>
> CS7206-M9-2 uptime is 4 days, 1 hour, 0 minutes
> System returned to ROM by reload at 14:00:16 MSK Thu Dec 20 2001
> System restarted at 14:06:22 MSK Thu Dec 20 2001
> System image file is "disk0:c7200-js-mz.122-2.T1.bin"
>
> cisco 7206VXR (NPE400) processor (revision A) with 245760K/16384K bytes of memory.
> Processor board ID 25855429
> R7000 CPU at 350Mhz, Implementation 39, Rev 3.2, 256KB L2, 4096KB L3 Cache
> 6 slot VXR midplane, Version 2.2
>
> Last reset from power-on
> Bridging software.
> X.25 software, Version 3.0.0.
> SuperLAT software (copyright 1990 by Meridian Technology Corp).
> TN3270 Emulation software.
> 1 Ethernet/IEEE 802.3 interface(s)
> 1 FastEthernet/IEEE 802.3 interface(s)
> 1 Gigabit Ethernet/IEEE 802.3 interface(s)
> 125K bytes of non-volatile configuration memory.
>
> 46976K bytes of ATA PCMCIA card at slot 0 (Sector size 512 bytes).
> 8192K bytes of Flash internal SIMM (Sector size 256K).
> Configuration register is 0x102
>
>
> ----------------
> SY, Jen Lin'kova aka Furry jen@rambler-co.ru
-- Jared Mauch | pgp key available via finger from jared@puck.nether.net clue++; | http://puck.nether.net/~jared/ My statements are only mine.
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:26 EDT