RE: [nsp] Cisco2500 Does not show AUI

From: Stefan.Gasteiger@Gendorf.de
Date: Thu Jan 24 2002 - 10:25:05 EST


On Thu, Jan 24, 2002 9:06 AM, Gert Doering wrote:
> On Thu, Jan 24, 2002 at 09:48:51AM -0500, Birsen Ozturk wrote:
> > There is a Cisco2500 that has one 10BaseT and one AUI port,
> > but when you run "sho ip bgp summ" it shows only Ethernet0.
> > I want to use both ethernets. How
> > can I manage that? I would appreciate ant idea.
[..]
> I'm not sure about more recent variants, but if the box
> claims it has only
> Ethernet0 ("show version" will also clarify this) it seems as
> if it's in
> the 1600 and similar series - it has 10BaseT and AUI, but
> they are wired
> to the same ethernet chip, so no way to use them simultaneously.

Yes, and you may set your connector by using the "media-type" command.
You can see, if Ethernet0 offers different connectors by doing this:
2500(config)#interface ethernet 0
2500(config-if)#media-type ?
 10BaseT Use RJ45 connector
 AUI Use AUI connector

--
Stefan