I had endless problems of getting OSPF to work over a BRI link
one side would say it had loaded fully and the other side said
it was continually retransmitting.
The TAC said put "ip mtu 1500" on both ends of the BRI and it
worked then. However they were vague about why it was needed
as I had tested the same config in a different code stream with
the mtu statement without problems. The TAC SE says its
not a bug.
I now about mtu mismatch in OSPF however it is always the L2
mtu I thought at least thats what the docs mention on CCO.
Regards,
Kevin
**********************************************************************
This email and any files transmitted with it are confidential and
intended solely for the use of the individual or entity to whom they
are addressed. If you have received this email in error please notify
the system manager.
This footnote also confirms that this email message has been swept for the
presence of computer viruses.
For more information contact postmaster@lancomms.ie
phone + 353 1 4093000
fax + 353 1 4093001
**********************************************************************
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:33 EDT