You people never read my (2) posting, that says that "full-duplex" line from
interface config went missing when I was cut-n-pasting. Of course, both
sides are set to 100/FDX (I've tried HDX, too - sympthoms are exactly the
same). And yes, I did try a few different patch cables, that are known to be
good and working.
Right now situation looks very dim: I would blame it either on SE or a
backplane, because X5234 is a *completely* new blade, and X5225R that I had
before in this exactly the same switch did behave in absolutely the same
manner, so it must be something else than the port blade. Switch is on the
testing bed now, and nothing has been plugged into it that might have caused
it to blow since it arrived (for obvious reasons - it never worked as it
should!)
On Wed, Nov 10, 1999 at 12:56:36PM +0100, Christian Panigl, ACOnet/UniVie wrote:
> Hi Dmitri,
>
> >Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize
> >----- ---------- ---------- ---------- ---------- ---------
> > 5/1 293 197 0 0 0
> >
> >Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sen Runts Giants
> >----- ---------- ---------- ---------- ---------- --------- --------- ---------
> > 5/1 0 0 0 0 0 142 0
> >
> >And these counters keep on raising... Switch thinks that port is connected,
> >"LINK" LED is lit, but Router does not seem to think so...
>
> typical picture if your Cat is 100/FDX and your host/router is 100/HDX
>
> >2620's FastEther0/0 connected to 5/1 is:
> >
> >interface FastEthernet0/0
> > no ip address
> > no ip directed-broadcast
> > speed 100
>
> sounds like beeing default (half-duplex), a "show int FastEth0/0" will
> tell you, change it to "full-duplex".
>
> Good luck
> CP
SY,
-- (KD1350) CCNA Dmitri E. Kalintsev CDPlayer@irc Senior network engineer at NetActive Internet dek @ hades.uz phone: +27 (0)11 719-0333 fax: 444-8900 http://hades.uz UIN:7150410 cell +27 (0)82-336-1033
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:07 EDT