On 26-Mar-2002 jlewis@lewis.org wrote:
> Anyone ever seen errors like this? This is a 7206VXR NPE300 that had been
> deployed, and suddenly died. I've tried replacing all the processor
> memory with known good memory (from other routers). I've tried replacing
> the I/O memory as well, but didn't have an exact match...it would complain
> about that and have similar problems booting up. I've pulled all the PA
> cards.
[snip]
> *** System received a Cache Parity Exception ***
"Cache Parity Exception" implies to me that the CPU L2 cache memory is bad. You
probably need a replacement NPE.
-- Ryan O'Connell - CCIE #8147 <ryan@complicity.co.uk> http://www.complicity.co.uk