Anyone ever seen errors like this? This is a 7206VXR NPE300 that had been
deployed, and suddenly died. I've tried replacing all the processor
memory with known good memory (from other routers). I've tried replacing
the I/O memory as well, but didn't have an exact match...it would complain
about that and have similar problems booting up. I've pulled all the PA
cards.
Error: SysAD, data cache, fields: data, 1st dword
physical addr(21:3) 0x10DA2F0,
virtual address is imprecise.
Imprecise Data Parity Error
Imprecise Data Parity Error
=== Flushing messages (07:55:44 UTC Tue Mar 26 2002) ===
Buffered messages:
Queued messages:Free space check for bootflash:crashinfo_20020326-075544 failed
(1/639)
*** System received a Cache Parity Exception ***
signal= 0x14, code= 0xe463760b, context= 0x6139e520
PC = 0x604b8a9c, Cause = 0x2420, Status Reg = 0x34008002
System Bootstrap, Version 12.0(19990210:195103) [12.0XE 105], DEVELOPMENT SOFTWA
RE
Copyright (c) 1994-1999 by cisco Systems, Inc.
C7200 platform with 262144 Kbytes of main memory
-- ---------------------------------------------------------------------- Jon Lewis *jlewis@lewis.org*| I route System Administrator | therefore you are Atlantic Net | _________ http://www.lewis.org/~jlewis/pgp for PGP public key_________