RE: [nsp] 7206vxr gone bad

From: Ryan O'Connell (ryan-nsp@complicity.co.uk)
Date: Tue Mar 26 2002 - 09:50:23 EST


On 26-Mar-2002 jlewis@lewis.org wrote:
> Anyone ever seen errors like this? This is a 7206VXR NPE300 that had been
> deployed, and suddenly died. I've tried replacing all the processor
> memory with known good memory (from other routers). I've tried replacing
> the I/O memory as well, but didn't have an exact match...it would complain
> about that and have similar problems booting up. I've pulled all the PA
> cards.
[snip]
> *** System received a Cache Parity Exception ***

"Cache Parity Exception" implies to me that the CPU L2 cache memory is bad. You
probably need a replacement NPE.

-- 
Ryan O'Connell - CCIE #8147
<ryan@complicity.co.uk>
http://www.complicity.co.uk



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:09 EDT