Pls find the configs
interface BRI0/0
no ip address
encapsulation ppp
dialer rotary-group 0
isdn switch-type basic-net3
no cdp enable
!
interface BRI0/1
no ip address
encapsulation ppp
dialer rotary-group 0
isdn switch-type basic-net3
no cdp enable
!
interface Dialer0
ip address negotiated
encapsulation ppp
dialer in-band
dialer idle-timeout 40000
dialer string 2387275
dialer load-threshold 1 either
dialer-group 1
ppp authentication pap callin
ppp pap sent-username ttlblr password 7 111D0D094640090016
ppp multilink
ppp timeout multilink link remove 39000
ip route 0.0.0.0 0.0.0.0 Dialer0
----- Original Message -----
From: "Todd, Douglas M." <DTODD@PARTNERS.ORG>
To: "'Rakesh'" <rakesh.menon@tataisp.com>; <cisco-nsp@puck.nether.net>
Sent: Wednesday, April 03, 2002 7:27 PM
Subject: RE: [nsp] RTO in rotary-group
> Can you provide us with a config and some show commands:
>
> sh bri int
> sh ip route
> sh run
>
> ==DMT>
>
> > -----Original Message-----
> > From: Rakesh [SMTP:rakesh.menon@tataisp.com]
> > Sent: Wednesday, April 03, 2002 7:40 AM
> > To: cisco-nsp@puck.nether.net
> > Subject: [nsp] RTO in rotary-group
> >
> > Hi ,
> >
> > Have created a setup where i have created a dialer interface with 2 BRI
> > interfaces in it. This has been done using rotary-group cmd in each bri
> > interface. So both the BRIs dial onto the 3com RAS . But observing that
incase
> > 1 bri line goes down , getting continuous request time outs even though
the
> > other line is up and connected . On the line coming up ie back onto 2
bri
> > lines(4 channels) , then ping becomes normal after 2-3 min. Ideally
after some
> > 2-3 RTO's it should become normal. The default route in that router is
towards
> > the dialer. No other route exists. Could anyone help me out why this
could be
> > happening.
> >
> > Thx&Rgds
> > Rakesh
> >
> >
> > << File: Rakesh Menon.vcf >>
>
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:13:39 EDT