Can you provide us with a config and some show commands:
sh bri int
sh ip route
sh run
==DMT>
> -----Original Message-----
> From: Rakesh [SMTP:rakesh.menon@tataisp.com]
> Sent: Wednesday, April 03, 2002 7:40 AM
> To: cisco-nsp@puck.nether.net
> Subject: [nsp] RTO in rotary-group
>
> Hi ,
>
> Have created a setup where i have created a dialer interface with 2 BRI
> interfaces in it. This has been done using rotary-group cmd in each bri
> interface. So both the BRIs dial onto the 3com RAS . But observing that incase
> 1 bri line goes down , getting continuous request time outs even though the
> other line is up and connected . On the line coming up ie back onto 2 bri
> lines(4 channels) , then ping becomes normal after 2-3 min. Ideally after some
> 2-3 RTO's it should become normal. The default route in that router is towards
> the dialer. No other route exists. Could anyone help me out why this could be
> happening.
>
> Thx&Rgds
> Rakesh
>
>
> << File: Rakesh Menon.vcf >>