Hi all,
i have a rather strange phenomenon on a customer router (NPE400, 7206 with on Board GIGE):
When i remove the GIGE Fibre directly on the router, the interface goes down/down
if i either disable it on the switch or "break" the fibre in between, the interface stays up/up.
Anyone have an idea ?
MY open cisco case is: Call Nr. C766053
Greetings
Jan
-- Jan Ahrent Czmok - Senior Network Engineer - Access Networks Global Access Telecommunications, Inc. - Stephanstr. 3 - 60313 Frankfurt voice: +49 69 299896-35 - fax: +49 69 299896-66 - email: czmok@gatel.de