Re: POS problems

From: Steve Meuse (smeuse@bbnplanet.com)
Date: Wed Jan 05 2000 - 23:12:25 EST


At 04:47 PM 01/05/2000 -0800, Andy McConnell wrote:
>Check first to make sure one end (75xx end if you're using a 75xx<->GSR
>pair) is set "clock source internal".
>
>Since the line itself looks pretty clean, my guess is that the PATH layer
>isn't getting the timing right.
>
>In one case, our POS OC3 failed miserably until we set this. I can't say
>for sure if this will help you, since I didn't collect the data like you
>did :-)
>
>-Andy

I will have to say that Cisco is inconsistent on that topic. When I asked a
DE about which clock source we should use in telco provided circuits the
answer was basically "which ever works".

-Steve



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:08 EDT