Hi There,
    I've been trying without success for a few days now to get the 
cisco ip firewall auth-proxy feature working on a 12.0.7T 3640...
It works fine if I use tacacs+, but I either need:
1. Get a tacacs+ server working on Digital Unix 4.0d on an Alpha 1000
-or-
2. (Preferred) Get auth-proxy to work with radius.
I've tried all the configs specified in the guide book, but it still won't
work with radius...
Here's what I have right now:
 aaa new-model
 aaa authentication login default group radius
 aaa authorization auth-proxy default group radius
!
 ip auth-proxy auth-proxy-banner
 ip auth-proxy name testproxy http list 1
!
interface Ethernet0/0
 description inside interface
 ip address 192.168.44.112 255.255.255.0
 no ip directed-broadcast
 ip auth-proxy testproxy
!
ip http server
 ip http authentication aaa
Thanks in advance for any help.
-- Jason
Jason Vanick ----------------------------------------------- jason@oaknet.com
OAKNET Consulting - Private Internet Consulting and Software Design since '91
Voice: 630-736-8402        Fax: 630-736-8502       Web: http://www.oaknet.com
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:09 EDT