Re: [nsp] Catalyst ASP/Fore ASX-200 LANE interoperability

From: Martin Cooper (mjc64@cam.ac.uk)
Date: Fri Jun 09 2000 - 10:57:52 EDT


Scott F. Robohn <sfr@ccci.com> writes:

> Not exactly sure about this, but try the following on your
> ASP major interface (atm2/0/0):
>
> lane fixed-config-atm-address
>
> This tells the LEC to use the well-known-address (WKA) to
> reach the LECS. I don't think the ASP LEC is using this as
> a default and is trying to learn it via ILMI.
>
> I believe later versions of IOS default into using the WKA
> for the LECS if nothing is learned via ILMI or no hard-coded
> LECS-address is present for the LEC.

We're not having a problem *reaching* the LECS though -
it's just that it returns all zeros for the addresses
of the LES and BUS, as though the ELAN requested didn't
exist.

Apparently I was confused about the nature of the problem
though. It turns out that in fact the problem is not with
IOS 11.2(10)WA3(4) (which works fine), but with 12.0(1a)
5(5b) -- suggesting that it might well be an IOS buglet.

M.



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:13 EDT