I'm working with some folks who are trying to get a 3660 to accept a
couple of WIC-2T cards. They've purchased a two of them, along with
a NM-1E2W and put the two WICs in it. With 12.0(7)XK1 and 12.1.2T I
get the same behavior. The router appears to recognize the cards, but
the interfaces don't show up.
The system seems to be happy with the ethernet port on the NM-1E2W.
But unless there's some magic required to get the serial ports to
materialize, it doesn't seem happy with either WIC. I'm starting to
wonder if there isn't some weird compatibility issue here; perhaps
the NM-1E2W supports the WIC-1T but not the -2T?
I'm sure I'm missing something simple. Any ideas what it is?
--Jeff
router#sh ver
Cisco Internetwork Operating System Software
IOS (tm) 3600 Software (C3660-JS-M), Version 12.1(2)T, RELEASE SOFTWARE (fc1)
Copyright (c) 1986-2000 by cisco Systems, Inc.
Compiled Tue 16-May-00 19:43 by ccai
Image text-base: 0x60008900, data-base: 0x613B4000
ROM: System Bootstrap, Version 12.0(6r)T, RELEASE SOFTWARE (fc1)
ROM: 3600 Software (C3660-IS-M), Version 12.0(7)T, RELEASE SOFTWARE (fc2)
router uptime is 13 minutes
System returned to ROM by reload at 21:24:54 UTC Thu Jul 13 2000
System restarted at 21:26:11 UTC Thu Jul 13 2000
System image file is "flash:c3660-js-mz.121-2.T.bin"
cisco c3660 (R527x) processor (revision A0) with 59392K/6144K bytes of memory.
Processor board ID JAB0343862W
R527x CPU at 225Mhz, Implementation 40, Rev 10.0, 2048KB L2 Cache
Bridging software.
X.25 software, Version 3.0.0.
SuperLAT software (copyright 1990 by Meridian Technology Corp).
TN3270 Emulation software.
3660 Chassis type: ENTERPRISE
1 Ethernet/IEEE 802.3 interface(s)
2 FastEthernet/IEEE 802.3 interface(s)
2 HSSI network interface(s)
DRAM configuration is 64 bits wide with parity disabled.
125K bytes of non-volatile configuration memory.
32768K bytes of processor board System flash (Read/Write)
16384K bytes of processor board PCMCIA Slot0 flash (Read/Write)
Configuration register is 0x2102
router#sh diag
...
Slot 3:
Combo 1E, 2W Port adapter, 3 ports
Port adapter is analyzed
Port adapter insertion time unknown
EEPROM contents at hardware discovery:
Hardware revision 1.2 Board revision E0
Serial number 19312858 Part number 800-01789-05
Test history 0x0 RMA number 00-00-00
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 37 01 02 01 26 B0 DA 50 06 FD 05 00 00 00 00
0x30: 70 00 00 00 00 04 07 17 FF FF FF FF FF FF FF FF
WIC Slot 0:
Serial 2T (12in1)
Hardware revision 1.0 Board revision C0
Serial number 20548259 Part number 800-03181-01
Test history 0x0 RMA number 00-00-00
Connector type PCI
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 12 01 00 01 39 8A A3 50 0C 6D 01 00 00 00 00
0x30: 60 00 00 00 00 05 24 00 FF FF FF FF FF FF FF FF
WIC Slot 1:
Serial 2T (12in1)
Hardware revision 1.0 Board revision B0
Serial number 17154641 Part number 800-03181-01
Test history 0x0 RMA number 00-00-00
Connector type PCI
EEPROM format version 1
EEPROM contents (hex):
0x20: 01 12 01 00 01 05 C2 51 50 0C 6D 01 00 00 00 00
0x30: 58 00 00 00 99 12 14 00 FF FF FF FF FF FF FF FF
router#sh ip int bri
Interface IP-Address OK? Method Status Protocol
FastEthernet0/0 X.X.X.X YES NVRAM up up
FastEthernet0/1 X.X.X.X YES NVRAM up up
Hssi1/0 X.X.X.X YES NVRAM up up
Hssi2/0 X.X.X.X YES NVRAM up up
Ethernet3/0 unassigned YES NVRAM up down
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:14 EDT