Re: [nsp] RES: [nsp] Ethernet backup interface

From: Dmitri Kalintsev (dek@hades.uz)
Date: Fri Aug 04 2000 - 05:27:57 EDT


On Thu, Aug 03, 2000 at 02:04:19PM -0300, Loureiro, Rodrigo wrote:
> OK, I have forgotten this primary issue. The primary interfaces addresses
> must be on the same subnet, as the virtual address, so it won´t work this
> way.
>
> Does anyone have another idea ?

Use BVI's.

SY,

-- 
   CCNP,CCDP (R&S)                                   Dmitri E. Kalintsev
   CDPlayer@irc            Senior network engineer at NetActive Internet
   dek @ hades.uz                phone: +27 (0)11 719-0333 fax: 444-8900
   http://hades.uz                 UIN:7150410  cell  +27 (0)82-336-1033