[nsp] RES: [nsp] Ethernet backup interface

From: Loureiro, Rodrigo (rodrigo.loureiro@netstream.com.br)
Date: Thu Aug 03 2000 - 13:04:19 EDT


OK, I have forgotten this primary issue. The primary interfaces addresses
must be on the same subnet, as the virtual address, so it won´t work this
way.

Does anyone have another idea ?

Regards,

--

Rodrigo Loureiro

-----Mensagem original----- De: Zaheer Aziz [mailto:zaziz@cisco.com] Enviada em: quinta-feira, 3 de agosto de 2000 13:48 Para: Loureiro, Rodrigo; cisco-nsp@puck.nether.net Assunto: Re: [nsp] Ethernet backup interface

At 12:10 PM 08/03/2000 -0300, Loureiro, Rodrigo wrote: >Hi all, > >I´ve been thinking about put two 7513 fastethernet interfaces (same router) >connected to a Catalyst 2924 in backup mode. Is it possible to implement >this using the HSRP concept, i mean, setting up a virtual address on both >interfaces, preempt and priorities, knowing the two interfaces are placed in >the same router?

HSRP works on a same subnet interfaces. IOS does not allow same subnet to be configured on the same router. you need two routers for HSRP to work

Zaheer > > >Regards, >-- > >Rodrigo Loureiro >Systems Engineer - Netstream Telecom >