RE: [nsp] RES: [nsp] Ethernet backup interface

From: Marcio Pilotto (marcio.pilotto@intelig.net.br)
Date: Thu Aug 03 2000 - 13:15:04 EDT


Rodrigo,

in order to performe this solution you need to configure both fasteth
interfaces with the same IP Net number, and the Cisco routers do not allow
this one.

Check into the Open Forum at CCO, someone else has already asked this.

Marcio Pilotto
Data Network Engineer - Intelig Telecom

-----Original Message-----
From: Loureiro, Rodrigo [mailto:rodrigo.loureiro@netstream.com.br]
Sent: quinta-feira, 3 de agosto de 2000 13:28
To: 'Jamal Williams'
Cc: cisco-nsp@puck.nether.net
Subject: [nsp] RES: [nsp] Ethernet backup interface

So, if configure two fastethernet interfaces on the same router with the
same virtual IP address and different priorities, only the one with the
biggest priority will respond for the virtual address ARP resolution. And in
the case this interface goes down, the other one starts to respond to
virtual address ARP resolutions.

Am i correct?

Regards,

--

Rodrigo Loureiro Systems Engineer - Netstream Telecom

-----Mensagem original----- De: Jamal Williams [mailto:williamj@metrocon.com] Enviada em: quinta-feira, 3 de agosto de 2000 12:46 Para: Loureiro, Rodrigo Assunto: Re: [nsp] Ethernet backup interface

Esta mensagem usa um conjunto de caracteres que não é suportado pelo Internet Mail Service. Para visualizar o conteúdo original da mensagem,abra a mensagem anexada. Se o texto não for exibido corretamente, salve o anexo no disco e abra-o utilizando um vizualizador que possa exibir o conjunto de caracteres original.



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:15 EDT