Re: [nsp] BERT Tests

From: Shawn Morris (shawn@smorris.com)
Date: Tue Sep 12 2000 - 15:59:55 EDT


You need to put a loop up at the remote end first.

On Tue, Sep 12, 2000 at 03:30:30PM -0400, Ron.Fuller@3x.com wrote:
> Does anyone know the correct sequence of events required to run a BERT test
> on a 7206VXR with the PA-MC-8T1 cards? When I run the BERT tests I get
> errors that from what I see on CCO should be ignored. How do I know if the
> BERT test was actually run properly? Here's an example:
>
> CC-7206-000-01(config)#cont t1 5/3
> CC-7206-000-01(config-contro)#bert pattern 0s interval 10
> CC-7206-000-01(config-contro)#end
> CC-7206-000-01#sh cont t1 5/3
> T1 5/3 is up.
> Cablelength is long gain36 0db
> DSX1 BERT pattern : zeros
> DSX1 BERT sync : no sync
> DSX1 BERT sync count : 0
> DSX1 BERT interval : 10
> DSX1 BERT time remain : 10
> DSX1 BERT total errs : 23
> DSX1 BERT total k bits: 0
> DSX1 BERT errors (last): 0
> DSX1 BERT k bits (last): 0
> Applique type is Channelized T1
> Description: Controller for the T-1 to Store #26
> No alarms detected.
> Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
> Data in current interval (584 seconds elapsed):
> 0 Line Code Violations, 0 Path Code Violations
> 0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
> 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
>
> CC-7206-000-01#sh cont t1 5/3
> T1 5/3 is up.
> Cablelength is long gain36 0db
> DSX1 BERT pattern : zeros
> DSX1 BERT sync : no sync
> DSX1 BERT sync count : 0
> DSX1 BERT interval : 10
> DSX1 BERT time remain : 10
> DSX1 BERT total errs : 46
> DSX1 BERT total k bits: 0
> DSX1 BERT errors (last): 0
> DSX1 BERT k bits (last): 0
> Applique type is Channelized T1
> Description: Controller for the T-1 to Store #26
> No alarms detected.
> Framing is ESF, Line Code is B8ZS, Clock Source is Internal.
> Data in current interval (593 seconds elapsed):
> 0 Line Code Violations, 0 Path Code Violations
> 0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
> 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
>
> We can see the total error counters increasing, but the status never goes
> into sync. It always says no sync. Any suggestions or help would be
> appreciated.
> We are running IOS 12.0(6)S
>
> Ron Fuller, CCIE #5851, CCDP, CCNP-ATM, CCNP-Security, MCNE
> 3X Corporation
> rfuller@3x.com



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:16 EDT