Re: NSE-1 experiences?

From: Cliff Judge (cliff@broccoli.cidera.com)
Date: Mon Sep 18 2000 - 12:24:28 EDT


I have had spontaneous reboot issues with 7206VXR's using the NPE300
processor and running 12.0(8)S

Each time the TAC tells me that well, looks like some memory failed
somewhere, but there was no way to tell where, and the entire router had
to be RMAed.

On Sun, 17 Sep 2000, Woxholt Vetle wrote:

> Hi,
> we recently experienced that a newly deployed Cisco 7206VXR with a NSE-1
> adapter installed rebooted itself.
> The IOS version installed is 12.1(2)E (which is required for the NSE-1).
>
> Have any other experienced problems with NSE-1 and IOS 12.1(2)E?
>
> The NSE-1 documentation claims that both 12.1(2)E and 12.1(3)T supports
> NSE-1, but the 12.1(3)T release notes doesn't say that support for NSE-1 is
> included. What's correct?
>
> Any experiences so far with Cisco 7206 and 12.1(3)T?
>
> Output from the 'sh ver' command:
>
> Cisco Internetwork Operating System Software
> IOS (tm) 7200 Software (C7200-JS-M), Version 12.1(2)E, EARLY DEPLOYMENT
> RELEASE
> SOFTWARE (fc1)
> Copyright (c) 1986-2000 by cisco Systems, Inc.
> Compiled Wed 21-Jun-00 09:29 by linda
> Image text-base: 0x60008900, data-base: 0x61476000
>
> ROM: System Bootstrap, Version 12.0(20000211:194150) [dperez-cosmos_e_ecc
> 106],
> DEVELOPMENT SOFTWARE
>
> xxxx uptime is 4 minutes
> System returned to ROM by bus error at PC 0x6041089C, address 0x4 at
> 21:25:03 CE
> T Sat Sep 16 2000
> System restarted at 21:26:50 CET Sat Sep 16 2000
> System image file is "slot0:c7200-js-mz.121-2.E.bin"
>
> cisco 7206VXR (NSE-1) processor (revision A) with 122880K/8192K bytes of
> memory.
> Processor board ID 20399677
> R7000 CPU at 262Mhz, Implementation 39, Rev 2.1, 256KB L2, 2000KB L3 Cache
> 6 slot VXR midplane, Version 2.0
>
> Last reset from power-on
> Bridging software.
> X.25 software, Version 3.0.0.
> SuperLAT software (copyright 1990 by Meridian Technology Corp).
> TN3270 Emulation software.
> PXF processor tmc is running.
> 3 FastEthernet/IEEE 802.3 interface(s)
> 1 ATM network interface(s)
> 125K bytes of non-volatile configuration memory.
>
> 20480K bytes of Flash PCMCIA card at slot 0 (Sector size 128K).
> 4096K bytes of Flash internal SIMM (Sector size 256K).
> Configuration register is 0x2102
>
> - Vetle
>
>

-%
Cliff Judge Network Engineer
301-598-0500 x2866 Cidera, Inc



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:17 EDT