RE: RE: [nsp] Connected routes missing after reboot

From: Scott.Keoseyan@BroadWing.com
Date: Thu Nov 09 2000 - 16:49:50 EST


Turns out to be a bug in IOS... CSC-DR49656

thanks for the comments tho

Scott

-----Original Message-----
From: Aaron Weintraub [mailto:aaronw@distracted.org]
Sent: Thursday, November 09, 2000 11:18 AM
To: Keoseyan, Scott (Broadwing)
Subject: Re: RE: [nsp] Connected routes missing after reboot

On Wed, Nov 08, 2000 at 09:46:29AM -0600, Scott.Keoseyan@BroadWing.com
wrote:
> That was my original assumption. I was using dCEF so I disabled the
> route-cache on the interface but it didn't help. I think this might be a
> hardware problem or maybe a problem on the microcode of the PA... we just
> logged into the VIP and the it is telling me the interface is down even
tho
> it is reported up at the CLI.

Even if you disable the route-cache on an interface, on a 75xx, the card
still has the CEF table in the DRAM of the card. If the VIP is telling
you down, but it's up on the router show int, then something is kinda
weird there...

aw