Here is the actual trace message...
%RSP-3-ERROR: dbus read at 3E841002
-Traceback= 60240290 60242894 60242E18 602461F0 601DDD2C 601DDDE0 601505F0
-Traceback= 60211AA8 60213624 601EDBBC 601E3060
%SYS-6-BOOT_MESSAGES: Messages above this line are from the boot loader
Richie Bowick
rb@mindspring.com
-----Original Message-----
From: Scott.Keoseyan@BroadWing.com [mailto:Scott.Keoseyan@BroadWing.com]
Sent: Tuesday, November 14, 2000 3:06 PM
To: rb@mindspring.com; cisco-nsp@puck.nether.net
Subject: RE: [nsp] 7505 and new VIP2-50 issue
Is the traceback accompanied by a "Unknown Port Adapter in Slot x" message
(or something to that effect) when it boots?
Scott
-----Original Message-----
From: Richie [mailto:rb@mindspring.com]
Sent: Tuesday, November 14, 2000 2:15 PM
To: cisco-nsp@puck.nether.net
Subject: [nsp] 7505 and new VIP2-50 issue
Has anyone experienced something like this...
I have a 7505 with a RSP4 installed. With no other cards installed, I
inserted a new VIP2-50 with a single fast ethernet (PA-FE) adapter. When I
boot the router, I receive a traceback message, the router continues to load
and I can perform a "show diag" and view the VIP information- memory is
correct,etc. When I power down the router and remove the fast ethernet
adapter and leave the VIP installed (for testing), the router continuously
reboots.
I have another VIP2-50 that works just fine. I have also tried updating the
IOS.
Just looking for some insight.
Richie Bowick
rb@mindspring.com
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:21 EDT