On Tue, 14 Nov 2000, Richie wrote:
> Has anyone experienced something like this...
>
> I have a 7505 with a RSP4 installed. With no other cards installed, I
> inserted a new VIP2-50 with a single fast ethernet (PA-FE) adapter. When I
> boot the router, I receive a traceback message, the router continues to load
> and I can perform a "show diag" and view the VIP information- memory is
> correct,etc. When I power down the router and remove the fast ethernet
> adapter and leave the VIP installed (for testing), the router continuously
> reboots.
Installing a VIP with no PAs is an unsupported configuration.
>
> I have another VIP2-50 that works just fine. I have also tried updating the
> IOS.
Did you update the bootflash?
>
> Just looking for some insight.
>
> Richie Bowick
> rb@mindspring.com
>
-Scott
-- Scott Whyte swhyte@cisco.com | Hobbes: "What would *you* call the Global Solutions Engineering | creation of the universe?" Network Design Consultant | CCIE 3340 | Calvin: "The Horrendous Space Kablooie!"
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:21 EDT