Re: [nsp] Traffic management for Colo centers

From: Bruce Robertson (bruce@greatbasin.net)
Date: Fri Dec 01 2000 - 19:54:46 EST


> I know that Catalyst 2948G-L3 switches do rate-limiting per interface,

I don't believe that this is true. You can configure it, but nothing
actually happens. Note the "shaping active no" in the second example:

rno-core1#sh traffic-shape f14

Interface Fa14
       Access Target Byte Sustain Excess Interval Increment Adapt
VC List Rate Limit bits/int bits/int (ms) (bytes) Active
- 400000 2500 10000 10000 25 1250 -

rno-core1#sh traffic-shape stat
            Access Queue Packets Bytes Packets Bytes Shaping
I/F List Depth Delayed Delayed Active
Fa14 0 0 0 0 0 no

rno-core1#sh int f14
  5 minute input rate 669000 bits/sec, 113 packets/sec

-- 
Bruce Robertson, President/CEO				     +1-775-348-7299
Great Basin Internet Services, Inc.			fax: +1-775-348-9412
For PGP key: finger bruce@greatbasin.net



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:22 EDT