Re: [nsp] Assymetrical DS3 errors?

From: J Bacher (jb@jbacher.com)
Date: Mon Jan 08 2001 - 10:02:25 EST


> Turned it on, but so far no effect has been seen. The LBO's are set to the
> actual cable length, because I am anal like that too. Tried setting them
> as low as 10 and as high as 450 to no avail.
>
> I may have to put a packet analyzer on both ends and see what's happening.

When I had this problem, the only fix was to put a 100ft coax from the
router to the fiber terminal.

I tried all options of configuration, worked with different length cables
and attenuators.



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:24 EDT