% Thomas Blauvelt wrote:
% > It is listed as a 'caveat' on the Cisco web page and was described as a
% > bug when I contacted the TAC (bug id is CSCdp33819). They recommended an
% > upgrade to 12.1(5)T which I haven't done because of the increased memory
% > requirements involved.
%
% Hi thomas,
%
% What do you mean by "increased memory reqirements" ?
%
% I have a bunch of 5300-240 with 64MB of memory each and I'm experiencing
% what seems to be a memory leak. The routers started eating memory when I
% switched from Radius to TACACS+ and I need a reload every 1-2 days.
%
% I'm pretty confident that it is a memory leak, but what is the memory
% requrement for 12.1(5)T on 5300s ?
I haven't noticed any increased memory requirements here on our 5300-192s
with 12.1T vs. 12.0T. Right around the point we started using TACACS,
12.0(7)T started leaking quite heavily. An upgrade to 12.1(1)T cleared it
up.
While we're on the topic of the 12.1 T-train, what's the current recommended
release to run in 12.1T on AS5300s?
% Daniele
john
-- John Morrissey _o /\ ---- __o RPA Internet _-< \_ / \ ---- < \, jwm@rpa.net __(_)/_(_)________/ \_______(_) /_(_)__