SV: [nsp] 3620 hardware/software problem

From: Jan Gunnik Hope (jangunnik.hope@idcomnet.no)
Date: Sun Jan 21 2001 - 08:57:12 EST


Yes, thank you both for pinpointing the problem,
and sorry about going off-thread.

When I knew what I was looking for, I found it documented
at :
        http://www.cisco.com/univercd/cc/td/doc/pcat/sewn__y2.htm

jgh

> > > I have a problem getting a 3620 to work correctly.
> > > I have tried locating the correct software form
> > > http://www.cisco.com/cgi-bin/front.x/Support/HWSWmatrix/hwswmatrix.cgi
> > > but have not succeded.
> > >
> > > Setup:
> > > Cisco 3620
> > > Slot 0 : NM-4T
> > > Slot 1 : NM-1E2W with :
> > > WIC 0 slot : WIC-2T
> WIC-2T does not operate in NM-1E2W
>
> > > WIC 1 slot : empty
> > >
> > > The router boots OK, but reports only 4 Serials.
> > > I.e. the WIC-2T is not detected
> > >
> > > Ideas anyone ?
> Use NM-1FE2W, NM-2FE2W or NM-2W for placing WIC-2T
>



This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:25 EDT