Vinod,
Apart from others suggested, you could also try to put them into one bridge group, and create a BVI interface.
HTH
Kent Yu
----- Original Message -----
From: Vinod Anthony Joseph Cherunni
To: cisco-nsp@puck.nether.net
Sent: Wednesday, March 07, 2001 8:54 AM
Subject: [nsp] REG: Dual Ethernet Ports on Cisco 7206-VXR
Dear All,
In a Cisco 7206-VXR with two Ethernet ports (One avaialable on the NPE-300, & another as a module), Is it not possible to build system level redundancy by physically connecting both the ports on a single switch. I am unable to define both ports to be part of the same IP subnet. Is there any workaround for this.
Kindly enlighten me
With warm regards,
Vinod.
This archive was generated by hypermail 2b29 : Sun Aug 04 2002 - 04:12:31 EDT