Hi,
On Fri, Mar 09, 2001 at 07:11:21PM +0100, Christian Panigl, ACOnet/VIX/UniVie wrote:
> We have disabled "flow cache" on the PA-2FE interfaces because of
> CSCdt07408 and verified that we are not running into CSCdt39968 and
> actually are now using IOS12.0(15)S1.
With 12.0(15)S1, watch out for "5 minute output rate" values (if you
use them) - if the output byte counter wraps around 4 Gbyte, the
output rate explodes. We've seen > 3 Gbit/sec. on a PA-FE...
(Case is being worked on).
gert
-- USENET is *not* the non-clickable part of WWW! //www.muc.de/~gert/ Gert Doering - Munich, Germany gert@greenie.muc.de fax: +49-89-35655025 gert.doering@physik.tu-muenchen.de