problem with mls ipx on 6500

From: kevin burts (burtsbee2000@yahoo.com)
Date: Fri Mar 23 2001 - 12:48:22 EST


Mod Slot Ports Module-Type Model
      Sub Status
--- ---- ----- -------------------------
------------------- --- --------
1 1 2 1000BaseX Supervisor
WS-X6K-SUP1A-2GE yes ok
15 1 1 Multilayer Switch Feature WS-F6K-MSFC2
      no ok
2 2 24 100BaseFX MM Ethernet
WS-X6324-100FX-MM no ok
4 4 48 10/100BaseTX Ethernet
WS-X6348-RJ-45 no ok

Mod Module-Name Serial-Num
--- ------------------- -----------
1 SAD050105ZK
15 SAD05010ANP
2 SAD0446000E
4 SAD04260MFF
switch info....
Mod MAC-Address(es) Hw Fw
      Sw
--- -------------------------------------- ------
---------- ------------
1 00-02-7e-26-a3-62 to 00-02-7e-26-a3-63 7.0
5.3(1) 6.1(2)
    00-02-7e-26-a3-60 to 00-02-7e-26-a3-61
    00-04-9b-2c-f0-00 to 00-04-9b-2c-f3-ff
15 00-04-c1-98-65-00 to 00-04-c1-98-65-3f 1.1
12.1(4)E1 12.1(4)E1
2 00-01-c9-6b-c4-0c to 00-01-c9-6b-c4-23 1.1
5.4(2) 6.1(2)
4 00-02-7e-f0-10-e0 to 00-02-7e-f0-11-0f 1.4
5.4(2) 6.1(2)

******
rp info

c6msfc2-js-mz-121-4.E1

******
the problem is mls for ip works fine
i can see entry on switch
but for ipx
i do not see any entry.

i have not disabled it on rp.
no statement is entered on rp related to mls

any idea?

__________________________________________________
Do You Yahoo!?
Get email at your own domain with Yahoo! Mail.
http://personal.mail.yahoo.com/