[nsp] trouble setting up a T3 crossover

From: jlewis@lewis.org
Date: Sat Mar 24 2001 - 00:51:07 EST


I'm trying to setup a T3 between a Cisco 7500 and 3640 in the same room
just to get the gear tested before deploying it. The 7500 is using a
couple of PA-2T3's. The 3640 has an NM-1HSSI and a Kentrox T3 IDSU. I've
got a pair of short coax cables (maybe 4 feet) going from xmit to rcv
between one of the PA-2T3 T3 interfaces and the IDSU.

I'm having trouble getting the T3 to run 100% clean. After playing with
lots of settings, I think I've found that the IDSU and and PA-2T3 don't
get along with scrambling enabled. The link will work, but takes lots of
errors.

With the framing on each end set to c-bit, one end set to get clock from
the line, one set to internal, and scramble off, I can pass lots of
traffic...but I get small numbers of receive CRC errors on the 7500.

Router#sh in s2/0/1
Serial2/0/1 is up, line protocol is up
  Hardware is cyBus PODS3 Serial
  Internet address is 10.255.255.1/30
  MTU 1500 bytes, BW 44210 Kbit, DLY 200 usec, rely 255/255, load 1/255
  Encapsulation HDLC, crc 16, loopback not set
  Keepalive set (10 sec)
  Last input 00:00:00, output 00:00:00, output hang never
  Last clearing of "show interface" counters 01:12:00
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  30 second input rate 0 bits/sec, 0 packets/sec
  30 second output rate 0 bits/sec, 0 packets/sec
     11311 packets input, 15123753 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
              0 parity
     10 input errors, 10 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
     13387 packets output, 16452239 bytes, 0 underruns
     0 output errors, 0 applique, 0 interface resets
     0 output buffer failures, 0 output buffers swapped out
     0 carrier transitions
     LC=up CA=down TM=down LB=down TA=down LA=down

Router#sh contr ser 2/0/1
Serial2/0/1 -
   Mx T3(2) HW Revision 0x3, FW Revision 3.9
   Framing is c-bit, Clock Source is Line
   Bandwidth limit is 44210, DSU mode 1, Cable length is 10
   Data in current interval (673 seconds elapsed):
     2 Line Code Violations, 0 P-bit Coding Violation
     0 C-bit Coding Violation
     0 P-bit Err Secs, 0 P-bit Sev Err Secs
     0 Sev Err Framing Secs, 0 Unavailable Secs
     1 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Sev Err Secs
   Total Data (last 4 15 minute intervals):
     17 Line Code Violations, 8 P-bit Coding Violation,
     8 C-bit Coding Violation,
     6 P-bit Err Secs, 0 P-bit Sev Err Secs,
     0 Sev Err Framing Secs, 0 Unavailable Secs,
     14 Line Errored Secs, 6 C-bit Errored Secs, 0 C-bit Sev Err Secs

   No alarms detected.

   Configured for remote default subrate

I've tried replacing the T3 cables (made a new set). It seems to have
slightly more trouble with patterns of alternating 0's and 1's (0xAAAA)
than the default pattern or all 0's or all 1's.

Have I overlooked something?

-- 
----------------------------------------------------------------------
 Jon Lewis *jlewis@lewis.org*|  I route
 System Administrator        |  therefore you are
 Atlantic Net                |
_________ http://www.lewis.org/~jlewis/pgp for PGP public key_________